Rated Power
60kW
Dimensions
132mm (H) × 410mm (W) × 500mm (D)
Weight
< 48kg
Efficiency
> 97% (Rated output)

Liquid Cooling AC-DC Module · Liquid Cooling Module

Excellent advantages

Ultra-high full-load operating temperature 50℃

MXR150060BL can output full power at 50°C. Effectively ensuring the charging speed in high temperature environment.

Ultra-wide output constant power range 375Vdc-1500Vdc

MXR150060BL's ultra-wide output voltage range and Ultra-high output power are suitable for charging various electric vehicles and greatly improve the charging speed.

Main features

  • Ultra-wide output voltage range, 200-1500VDC, suitable for a wide range of EVs; Ultra-high output power, in 375V-1500V output voltage, 60KW constant power output.
  • Wide operating temperature range at -40℃ ~ +70℃.
  • Full load efficiency is higher than 97%, high efficiency in the whole working range, and more power saving.
  • Ultra-low noise, enhance user charging experience.
  • The current in the low-voltage area does not shrink, and the charging speed is faster.
  • The module is built with residual voltage relief circuit to reduce system cost and improve system reliability.

Technical specifications

Basic Indicators

Dimensions
132mm (H) × 410mm (W) × 500mm (D)
Weight
< 48kg
Rated Power
60kW
Communication Method
CAN
Parallel Quantity
≤ 60pcs (customization is acceptable)
Efficiency
> 97% (Rated output)
Power Factor
> 0.99 (load ≥ 50%)
ITHD
≤ 5% (load ≥ 50%)

AC Input Characteristics

Input Voltage
260Vac ~ 530Vac, three-phase + PE
Input Current
0 ~ 115A

DC Output Characteristic

Voltage Range
200 ~ 1500Vdc (continuously adjustable)
Current Range
0A ~ 160A (continuously adjustable)

Cooling System

Cooling Method
Liquid cooled
Coolant
Deionized water, water plus ethylene glycol
Inlet temperature
< 70℃
Liquid Flow
10L/min

Others

Voltage Stabilization Accuracy
≤ ± 1%
Current Stabilization Accuracy
≤ ± 0.5%
Ripple Peak
≤ 1%
Operating Temperature
-40℃ ~ +70℃, output derating at above 50℃
Altitude
≤ 2000m, output derating above 2000m