Dimensions
100mm (H) × 340mm (W) × 470mm (D)
Weight
≤ 28kg
Efficiency (full load)
> 95.5%
Cooling Mode
Liquid cooling

Liquid Cooling AC-DC Module · Liquid Cooling Module

Excellent advantages

Ultra-high full-load operating temperature 60℃

MXR100040L can output full power at 60°C. Effectively ensuring the charging speed in high temperature environment.

Ultra-wide output constant power range 300Vdc-1000Vdc

MXR100040L's ultra-wide output voltage range and Ultra-high output power are suitable for charging various electric vehicles and greatly improve the charging speed.

Main features

  • Ultra-wide output voltage range, 50-1000VDC, suitable for a wide range of EVs.
  • Ultra-high output power, in 300V-1000V output voltage, 40KW constant power output.
  • Wide operating temperature range at -40℃ ~ +75℃.
  • Full load efficiency is higher than 95.5%, high efficiency in the whole working range, and more power saving.
  • Ultra-low noise, enhance user charging experience.
  • The current in the low-voltage area does not shrink, and the charging speed is faster.
  • The module is built with residual voltage relief circuit to reduce system cost and improve system reliability.

Technical specifications

Basic Indicators

Dimensions
100mm (H) × 340mm (W) × 470mm (D)
Weight
≤ 28kg
Efficiency (full load)
> 95.5%
Standby Power Consumption
13W ± 0.5W
Cooling Mode
Liquid cooling
Communication Method
CAN bus
Parallel Modules Quantity
≤ 60pcs
Indicator Light
Green: Normal operation; Yellow: Protection alarm; Red: Fault alarm; LED digital tube

Input Characteristics

Input Voltage
260Vac ~ 530Vac, three phase + PE
Input Current
< 80A
Grid Frequency
45Hz ~ 65Hz
Power Factor
≥ 0.95 (8kW ≤ output power ≤ 20kW); ≥ 0.98 (20kW ≤ output power ≤ 40kW)
ITHD
≤ 5% (20kW ≤ output power ≤ 40kW)

Output Characteristic

Voltage Range
50Vdc ~ 1000Vdc
Current Range
0A ~ 133.3A (continuously regulated)
Rated Current
40A
Voltage Stabilization Accuracy
≤ ± 0.5% (Stabilized voltage state, input voltage 323Vac ~ 456Vac, output voltage 200Vdc ~ 1000Vdc, output current 0 ~ rated current value)
Current Stabilization Accuracy
≤ ± 1% (Steady current state, input voltage 323Vac ~ 456Vac, output voltage 200Vdc ~ 1000Vdc, output current 20% rated current ~ 100% rated current value)
Current Imbalance
≤ ± 3%
Ripple Factor (Peak to Peak)
≤ 1% (voltage stabilization status, input voltage 323Vac ~ 456Vac, output voltage 200Vdc ~ 1000Vdc, output current 0 ~ rated current)

Environmental Specifications

Operating Temperature
-40℃ ~ +75℃, output derating above 60℃
Storage Temperature
-40℃ ~ +75℃
Relative Humidity
≤ 95%RH, Non-condensing
Altitude
≤ 2000m (Derating above 2000m. The operating temperature decreases by 1℃ for each additional 100m when above 1000m)
MTBF
> 500,000 hours

Cooling System

Flow
6L/min ~ 10L/min (60%: 40% ethylene glycol aqueous solution)
Temperature
-40℃ ~ +75℃, derating is required for use above 60℃
Coolant
60%: 40% ethylene glycol aqueous solution
Inlet and outlet liquid pressure difference
< 10kPa @ 10L/min flow rate
Storage Volume
0.21L (module flow channel liquid storage volume)

EMC

Emission
CLASS B, Reference standard: IEC 61000-6-3
Immunity
CLASS B, Reference standard: IEC 61000-6-1

Certification

CE/TUV
IEC61851-1
TUVus
UL2202