Liquid Cooling Module
FUPLA0601000L-W2S
60KW@1000V High Protective Liquid Cooling EV DC Charging Power Module
Click to zoomTap to zoom- Rated Power
- 60kW
- Dimensions
- 132mm (H) × 410mm (W) × 500mm (D)
- Weight
- < 48kg
- Efficiency
- > 96.5% (Rated output)
Liquid Cooling AC-DC Module · Liquid Cooling Module
Excellent advantages
Ultra-high full-load operating temperature 50℃
MXR100060BL can output full power at 50°C. Effectively ensuring the charging speed in high temperature environment.
Ultra-wide output constant power range 300Vdc-1000Vdc
MXR100060BL's ultra-wide output voltage range and ultra-high output power are suitable for charging various electric vehicles and greatly improve the charging speed.
Main features
- Ultra-wide output voltage range, 200-1000VDC, suitable for a wide range of EVs.
- Ultra-high output power, in 300V-1000V output voltage, 60KW constant power output.
- Wide operating temperature range at -40℃ ~ +70℃.
- Full load efficiency is higher than 96.5%, high efficiency in the whole working range, and more power saving.
- Ultra-low noise, enhance user charging experience.
- The current in the low-voltage area does not shrink, and the charging speed is faster.
- The module is built with residual voltage relief circuit to reduce system cost and improve system reliability.
Technical specifications
Basic Indicators
- Dimensions
- 132mm (H) × 410mm (W) × 500mm (D)
- Weight
- < 48kg
- Rated Power
- 60kW
- Communication Method
- CAN
- Parallel Quantity
- ≤ 60pcs (customization is acceptable)
- Efficiency
- > 96.5% (Rated output)
- ITHD
- ≤ 5% (load ≥ 50%)
- Standby Power Consumption
- < 12W
AC Input Characteristics
- Input Voltage
- 260Vac ~ 530Vac, three-phase + PE
- Input Current
- 0A ~ 115A
- Power Factor
- > 0.99 (load ≥ 50%)
- Current Harmonics
- < 5% (load ≥ 50%)
DC Output Characteristic
- Voltage Range
- 200 ~ 1000Vdc (continuously adjustable)
- Current Range
- 0A ~ 200A (continuously adjustable)
- Voltage Stabilization Accuracy
- < ± 1%
- Current Stabilization Accuracy
- < ± 0.5%
- Ripple Factor
- < 1%
Cooling System
- Liquid Flow
- > 10L/min
- Water Pressure Drop
- < 50kPa @10LPM
- Maximum Inlet Pressure
- 250kPa
- Coolant
- Deionized water, water plus ethylene glycol
- Inlet Temperature
- -40℃ ~ +70℃ (Derating at above 50℃)
Environmental Conditions
- Altitude
- ≤ 2000m (Derating above 2000m.)
- Working Environment
- Temperature: -40 ~ 70℃; Humidity: < 95%
- Storage Environment
- Temperature: -40 ~ 70℃; Humidity: < 95%
Others
- EMC
- Meets IEC61000-6-2, IEC61000-6-4
- Safety
- Meets IEC60664-1
Certification
- Dielectric Strength
- Input/Output: 4500Vdc/<10mA/1MIN; Input/Output/Ground: 4500Vdc/<10mA/1MIN; Input/Output/communication: 4500Vdc/<10mA/1MIN
- Insulation Resistance
- > 10MΩ



