Ultracapacitors · Bank assembly
Faradigm 100PP-75 Ultra-Capacitor Bank Assembly
100 V DC · 15 F · CAN health monitoring
- Operating voltage
- 100 V DC (120 V DC max)
- Capacitance
- 15 F ±10%
- Energy
- 75 kJ at 100 V DC
- Peak discharge
- 150 A for 500 msec
- Weight
- Not more than 17.5 kg
- Ingress protection
- IP21, natural cooling
An ultra-capacitor energy storage assembly for 100 VDC systems (120 VDC maximum), connected at the output of a DC power supply to keep power available to DC motor control through the motor drive. It delivers short, high-power bursts to the motor drive and supplements the DC power supply during peak load demand.
← Back to all ultracapacitorsBurst power for motor drives.
High-power bursts
25 A for 2 sec and a peak discharge of 150 A for 500 msec, repeatable at a duty cycle of 30 sec between two cycles.
Regenerative protection
Withstands up to 300 VDC produced during motor deceleration, with diode protection at the output built into the unit.
Health monitoring over CAN
Bus voltage, available charge, temperature and faults are available on CAN protocol through a 38999 connector.
Qualified for ground vehicle and defence
Built for applications that need JSS-55555:2020 and MIL-STD-461E EMI/EMC qualification.
- 75 kJ
- energy at 100 V DC
- 150 A
- peak discharge, 500 msec
- ≤ 65 mΩ
- typical DC ESR
- -30°C to +65°C
- operating temperature
Specifications
Full technical data.
| Model Number | 100PP-75 |
|---|---|
| Operating Voltage | 100V DC |
| Maximum Voltage | 120V DC |
| Regenerative Voltage | 300V DC (during motor deceleration, for a few milliseconds, ~500 ms); diode protection at output incorporated within the unit |
| Capacitance | 15F |
|---|---|
| Capacitance Tolerance | ±10% |
| Energy | 75kJ at 100V DC |
| Typical DC ESR | ≤ 65 mΩ |
| Discharge Current (Nominal) | 25A for 2000 msec |
|---|---|
| Peak Discharge Current | 150A for 500 msec |
| Duty Cycle | 30 sec between two cycles |
| Charging Current | 5A, constant current charging |
|---|
| Short Circuit / Over Current | Protected using suitably rated fuse |
|---|---|
| Over Temperature | Provided |
| Control Voltage (Internal Circuitry) | External 28V DC, 1A ± 15%, isolated power supply via 38999 connector |
|---|---|
| Health Status | Bus voltage, available charge, temperature, fault, etc. on CAN protocol via 38999 connector |
| Input | MIL-duty type / 38999 or equivalent |
|---|---|
| Output | MIL-duty type / 38999 or equivalent |
| Electrical Wiring | PTFE grade Teflon wires |
| Dimension (L x W x H) | 400 ±5 x 259 ±5 x 300 ±3 mm |
|---|---|
| Weight | Not more than 17.5 kg |
| Material | Enclosure, clamp and fasteners in SS / Aluminium grade to avoid rust and corrosion; rubber material / gasket selected to avoid mould growth |
| Colour | Powder coating, Dove Gray, Shade No. 694 of IS 5, matt finish |
| Ingress Protection | IP21 |
| Cooling | Natural |
| Operating Temperature | -30°C to +65°C |
|---|---|
| Storage Temperature | -40°C to +85°C |
| ESS Test compliance design | 1. Random vibration: 20-80 Hz (+3 dB/octave), 80-350 Hz at 0.03 g²/Hz constant, 350-2000 Hz (-3 dB/octave); gRMS = 4; 5 min/axis in all three axes / 2. Thermal cycling: -20°C to +55°C, dwell time 60 min, 10 cycles, rate of change 5°C/min / 3. Random vibration: as in 1, with 0.02 g²/Hz constant level; gRMS = 4; 5 min/axis in all three axes |
| EMI-EMC Compliance | MIL-STD-461E, Army ground application / CE 102, RE 102, CS 101, CS 114, CS 115, CS 116, RS 103, HESD |
| Qualification Test | As per JSS-55555:2020 / Vibration, high temperature, damp heat, low temperature, altitude, rapid temperature cycling, tropical exposure, corrosion (salt), mould growth, bump |