EV Charger Module AC-DC
FUPLA0200120F-W2C
20KW@120V Low Voltage & High Current Charging Module
Click to zoomTap to zoom- Dimensions
- 84mm (H) x 218mm (W) x 459mm (D)
- Weight
- ≤ 12kg
- Efficiency (full load)
- > 93.5%
- Cooling Method
- Fan cooling
Low Voltage & High Current Module · EV Charger Module AC-DC
Excellent advantages
Ultra-wide output voltage range 20V-120V
The ultra-wide output voltage range of MXR100200B can meet the charging requirements of low voltage.
Super charging current 200A
The super charging current of MXR100200B can greatly reduce the charging time.
Main features
- Wide output voltage range, 20~120VDC, suitable for low-speed EVs.
- Wide operating temperature range at full power, -40℃ ~ +50℃.
- Full load efficiency is higher than 93.5%, high efficiency in the whole working range, and more energy saving.
- Ultra-low standby power consumption, the whole series of products are controlled within 8W.
- The current in the low-voltage area does not shrink, and the charging speed is faster.
- The module is built with residual pressure relief loop to reduce system cost and improve system reliability.
Characteristic curves

Technical specifications
Basic Indicators
- Dimensions
- 84mm (H) x 218mm (W) x 459mm (D)
- Weight
- ≤ 12kg
- Efficiency (full load)
- > 93.5%
- Standby Power Consumption
- 8.5W ± 0.5W
- Cooling Method
- Fan cooling
- Communication Mode
- CAN bus
- Parallel Quantity
- ≤ 60
- Indicator Light
- Green: normal operation; Yellow: alarm; Red: failure
AC Input Characteristics
- Input Voltage
- 190Vac ~ 530Vac, three phase + PE
- Input Current
- < 40A
- Input Frequency
- 45Hz ~ 65Hz
- Power Factor
- ≥ 0.99 @50% ~ 100% full load output power
- ITHD
- ≤ 5% @50% ~ 100% full load output power
DC Output Characteristics
- Voltage Range
- 20Vdc - 120Vdc
- Current Range
- 0A ~ 200A (continuously adjustable)
- Rated Current
- 200A
- Voltage Stabilization Accuracy
- ≤ ± 0.5%
- Current Stabilization Accuracy
- ≤ ± 1% (Output load 20% ~ 100% rated range)
- Current Imbalance
- ≤ ± 5%
- Ripple Factor (Peak to Peak)
- ≤ 1%
Environmental Conditions
- Operating Temperature
- -40℃ ~ +75℃, Output derating above 50℃
- Storage Temperature
- -40℃ ~ +75℃
- Relative Humidity
- ≤ 95% RH, Non-condensing
- Altitude
- ≤ 1000m (Derating above 1000m. The operating temperature decreases by 1℃ for each additional 100m)
- MTBF
- > 500,000 hours
Alarm and Protection
- Input OverVoltage/Undervoltage Protection
- Automatic recovery after shutdown
- Output Overvoltage Protection
- Manual recovery after shutdown
- Over Current And Short Circuit Protection
- Manual recovery after shutdown
- Over Temperature Protection
- Automatic recovery after shutdown
Certification
- cTUVus
- Test specification: UL 1564: 2015 R8.17; CSA C22.2 No. 107.2