Skip to content
EV Charger Module AC-DC

FUPLA0200120F-W2C

20KW@120V Low Voltage & High Current Charging Module

FUPLA0200120F-W2C — 20KW@120V Low Voltage & High Current Charging ModuleTap to zoom
Dimensions
84mm (H) x 218mm (W) x 459mm (D)
Weight
≤ 12kg
Efficiency (full load)
> 93.5%
Cooling Method
Fan cooling

Low Voltage & High Current Module · EV Charger Module AC-DC

Excellent advantages

Ultra-wide output voltage range 20V-120V

The ultra-wide output voltage range of MXR100200B can meet the charging requirements of low voltage.

Super charging current 200A

The super charging current of MXR100200B can greatly reduce the charging time.

Main features

  • Wide output voltage range, 20~120VDC, suitable for low-speed EVs.
  • Wide operating temperature range at full power, -40℃ ~ +50℃.
  • Full load efficiency is higher than 93.5%, high efficiency in the whole working range, and more energy saving.
  • Ultra-low standby power consumption, the whole series of products are controlled within 8W.
  • The current in the low-voltage area does not shrink, and the charging speed is faster.
  • The module is built with residual pressure relief loop to reduce system cost and improve system reliability.

Characteristic curves

Characteristic curves for FUPLA0200120F-W2C

Technical specifications

Basic Indicators

Dimensions
84mm (H) x 218mm (W) x 459mm (D)
Weight
≤ 12kg
Efficiency (full load)
> 93.5%
Standby Power Consumption
8.5W ± 0.5W
Cooling Method
Fan cooling
Communication Mode
CAN bus
Parallel Quantity
≤ 60
Indicator Light
Green: normal operation; Yellow: alarm; Red: failure

AC Input Characteristics

Input Voltage
190Vac ~ 530Vac, three phase + PE
Input Current
< 40A
Input Frequency
45Hz ~ 65Hz
Power Factor
≥ 0.99 @50% ~ 100% full load output power
ITHD
≤ 5% @50% ~ 100% full load output power

DC Output Characteristics

Voltage Range
20Vdc - 120Vdc
Current Range
0A ~ 200A (continuously adjustable)
Rated Current
200A
Voltage Stabilization Accuracy
≤ ± 0.5%
Current Stabilization Accuracy
≤ ± 1% (Output load 20% ~ 100% rated range)
Current Imbalance
≤ ± 5%
Ripple Factor (Peak to Peak)
≤ 1%

Environmental Conditions

Operating Temperature
-40℃ ~ +75℃, Output derating above 50℃
Storage Temperature
-40℃ ~ +75℃
Relative Humidity
≤ 95% RH, Non-condensing
Altitude
≤ 1000m (Derating above 1000m. The operating temperature decreases by 1℃ for each additional 100m)
MTBF
> 500,000 hours

Alarm and Protection

Input OverVoltage/Undervoltage Protection
Automatic recovery after shutdown
Output Overvoltage Protection
Manual recovery after shutdown
Over Current And Short Circuit Protection
Manual recovery after shutdown
Over Temperature Protection
Automatic recovery after shutdown

Certification

cTUVus
Test specification: UL 1564: 2015 R8.17; CSA C22.2 No. 107.2