Skip to content
EV Charger Module DC-DC

FUPLD0401000F-X5S

40KW@1000V DC-DC Charging Module

FUPLD0401000F-X5S — 40KW@1000V DC-DC Charging ModuleTap to zoom
Rated Power
40kW
Dimensions
85mm (H) × 360mm (W) × 459mm (D)
Weight
≤ 20kg
Efficiency (full load)
> 97.5%

DC-DC Charging Power Module · EV Charger Module DC-DC

Excellent advantages

Ultra-high full-load operating temperature 50℃

MXR100040-DC can output full power at 50℃. Effectively ensuring the charging speed in high temperature environment.

Ultra-wide input constant power range 400Vdc ~ 850Vdc

MXR100040-DC's ultra-wide output voltage range and Ultra-high output power are suitable for charging various electric vehicles and greatly improve the charging speed.

Main features

  • Ultra-wide output voltage range, 50-1000VDC, suitable for a wide range of EVs.
  • Wide operating temperature range at -40℃ ~ +75℃.
  • Full load efficiency is higher than 97.5%, high efficiency in the whole working range, and more power saving.
  • Ultra-low noise, enhance user charging experience.
  • The current in the low-voltage area does not shrink, and the charging speed is faster.
  • The module is built with residual voltage relief circuit to reduce system cost and improve system reliability.

Characteristic curves

Characteristic curves for FUPLD0401000F-X5S

Technical specifications

Basic Indicators

Dimensions
85mm (H) × 360mm (W) × 459mm (D)
Weight
≤ 20kg
Efficiency (full load)
> 97.5%
Cooling Mode
Fan cooling
Communication Method
CAN bus
Parallel Quantity
≤ 60pcs
Indicator
Green: normal operation; Yellow: alarm; Red: fault; LED digital tube

Input Characteristics

Input Voltage
200Vdc ~ 850Vdc
Input Current
≤ 90A
Constant Power Input Voltage
400Vdc ~ 850Vdc

Output Characteristic

Rated Power
40kW
Voltage Range
50Vdc ~ 1000Vdc
Current Range
0A ~ 133.3A (continuously regulated)
Rated Current
40A
Voltage Stabilization Accuracy
≤ ± 0.5% (100V-1000V, 0~20MHz)
Current Stabilization Accuracy
≤ ± 1% (Output current 20% ~ 100% rated current)
Current Imbalance
≤ ± 3%
Ripple Factor (Peak to Peak)
≤ 1%

Environmental Specifications

Operating Temperature
-40℃ ~ +75℃, output derating above 50℃
Storage Temperature
-40℃ ~ +75℃
Relative Humidity
≤ 95%RH, Non-condensing
Altitude
≤ 2000m (Derating above 2000m. The operating temperature decreases by 1℃ for each additional 100m)
MTBF
> 500,000 hours
ROHS
R6